Home > Hardware > CAN I/O Series >
CAN CBX REL interface with 4 opto-isolated relays
CAN-CBX-REL4
Item #: C.3012.02
Availability: Call For Pricing - (413) 772-3170 Usually ships In 2 Weeks
CAN-CBX-REL4
4 Relay Outputs
- CANopen module with In-rail Bus
- 4 relay outputs 2 change over contacts - 2 change over, 2 normally open contacts
- CAN/Canopen interface electrically isolated and designed acc. to ISO 11898
- Max. switching voltage 220 VDC/250 VAC,
- Max. switching current 8 A (AC & DC)
- Switching power:
- Max. resistive load: 2000 VA / 240 W
- Max. inductive load: 875 VA / 170 W
- Replacing individual modules from InRailBus without interrupting CAN or power feed
- Ambient temperature range -20 °C ... +70 °C
- Current loading: 2A at 30 VDC
- DS-401 CANopen I/O profile
- Firmware adaptable to customers' requirements and upgradeable via CANopen
- CANopen profiles DS-301, DS-401
Relay OutputsThe CAN-CBX-REL4 is equipped with 4 relays which are electrically isolated from each other. Therefore various voltages can be applied to the CAN-CBX-REL4 module simultaneously.
Compact I/O ModuleThe CAN-CBX module series with In-Rail- Bus provides industry compatible CAN bus in-/output modules in combination with service-friendly ‘wiring’ of CAN bus and supply voltage.
In-Rail-BusThe power supply and the CAN bus signals can be applied via the In-Rail-bus connector (TBUS-connector) integrated in the mounting rail or separately via the clampconnection. From the In-Rail-Bus individual modules can be removed without interrupting the bus signals.
CAN InterfaceThe CAN interface is designed according to ISO11898 with electrical isolation and bit rates up to 1 Mbit/s. The CANopen-node number and the CANbit rate can be easily set via coding switches.
LED DisplayFour LEDs show the I/O-channel state and the CANopen node state.
Software SupportThe module comes with CANopen firmware according to CiA-DS-301 and with a CANopen I/O-profile according to CiADS-401.
Technical Specifications
Relay Specifications |
Number of outputs: |
4 outputs: |
|
2x normally open, 2x change-over |
Switching voltage: |
max. 250 VAC, 125 VDC |
Switching current: |
max. 8 A (AC and DC) |
Switching power: |
max. resistive load: 2000 VA/240 W |
|
max. inductive load: 875 VA/170 W |
Switching frequency: |
max. 30 operations per minute |
Endurance mechanical load: |
100 000 cycles |
CAN, Microcontroller |
Microcontroller: |
MB90F497, ISO 11898-1 |
CAN interface: |
acc. to ISO 11898-2, differential, electrically isolated, bit rate up to 1 Mbit/s |
Protocol: |
CANopen DS-301, DS-401 |
General |
Ambient temperature: |
-20 /C ... +70 /C |
Power supply: |
nominal 24 VDC / 100 mA |
|
permitted range 18...30 VDC |
Dimensions: |
22 x 112 x 113 mm |
Connectors: |
Power: Phoenix MSTBO2,5/4-G1LKMGY |
|
CAN: Phoenix MC1,5/5-GF-3.81 |
|
I/O: Phoenix MC 1,5/10-G-5,08 |
Order Information
Designation |
|
order no. |
CAN-CBX-REL4 |
4 relay outputs including 1 CAN-CBX-TBUS In-Rail-Bus connector |
C.3000.01) |
CAN-CBX-REL4
4 Relay Outputs
- CANopen module with In-rail Bus
- 4 relay outputs 2 change over contacts - 2 change over, 2 normally open contacts
- CAN/Canopen interface electrically isolated and designed acc. to ISO 11898
- Max. switching voltage 220 VDC/250 VAC,
- Max. switching current 8 A (AC & DC)
- Switching power:
- Max. resistive load: 2000 VA / 240 W
- Max. inductive load: 875 VA / 170 W
- Replacing individual modules from InRailBus without interrupting CAN or power feed
- Ambient temperature range -20 °C ... +70 °C
- Current loading: 2A at 30 VDC
- DS-401 CANopen I/O profile
- Firmware adaptable to customers' requirements and upgradeable via CANopen
- CANopen profiles DS-301, DS-401
CAN-CBX-REL4
4 Relay Outputs
- CANopen module with In-rail Bus
- 4 relay outputs 2 change over contacts - 2 change over, 2 normally open contacts
- CAN/Canopen interface electrically isolated and designed acc. to ISO 11898
- Max. switching voltage 220 VDC/250 VAC,
- Max. switching current 8 A (AC & DC)
- Switching power:
- Max. resistive load: 2000 VA / 240 W
- Max. inductive load: 875 VA / 170 W
- Replacing individual modules from InRailBus without interrupting CAN or power feed
- Ambient temperature range -20 °C ... +70 °C
- Current loading: 2A at 30 VDC
- DS-401 CANopen I/O profile
- Firmware adaptable to customers' requirements and upgradeable via CANopen
- CANopen profiles DS-301, DS-401
Common Features of All CAN-CBX-Modules:
- Slim-line (22mm) DIN rail mounting enclosure
- Interconnection via InRailBus connector (CAN and power supply)
- Replacing modules from InRailBus without interrupting CAN or power feed Automatic function earth (FE) contact
- 2-wire or 3-wire connection of I/Os to meet industrial requirements
- CAN interface: ISO11898, electrically isolated, 1 Mbit/s
- Coding switches for Node-ID and bitrate preselection, status display via LEDs
- Power supply voltage 12 V...32V Environmental temperature range -20ºC...+70ºC DS-301 CANopen profile, DS-4xx CANopen I/O profile Firmware update via CAN Customer-specific firmware extensions reloadable Suitable for CANOpen and J1939.
|